Cannulated Femoral Nail (C.F.N) Specification, Uses, Sizes and Surgical Techniques:
Femur (Femoral) Nail is designed for varied use. A single nail can be used for both right and left standard interlocking procedures. The Femur (Femoral) Nail is available in the most commonly used sizes. These nails range in diameters from 8 mm to 14 mm and lengths from 240 mm to 420 mm.
Closed intramedullary nailing has long been a common method of treating noncomminuted fractures of the femur. The Femur (Femoral) Nail has extended the indications of closed intramedullary nailing to include comminuted fractures, fractures with bone loss, and proximal and distal fractures of the femur.
The multi-point fixation provided by the cross-section of the Femoral Nail makes it appropriate for use unlocked as well as locked in either the dynamic or static mode. It also makes it appropriate for reamed or unreamed applications. The successful use of Femur (Femoral) Nail is technically demanding. Close attention to positioning, reduction, rod placement, and insertion of the proximal and distal locking screws is mandatory.
IMPORTANT NOTICE: Customers Can Choose Different Size By Need. Send us Size with the Note of Your Order.
ITEM DESCRIPTION: 10 UNITS NAILS: Minimum order 5 Units for each Reference
Product Nº. Diameter, mm length, mm
401.340 -Diameter, 9mm-length-340mm
401.360 -Diameter, 9mm-length-360mm
401.380 -Diameter,9 mm-ength-380mm
401.400 -Diameter, 9mm-length-400mm
401.420 -Diameter, 9mm-length-420mm
401.440 -Diameter,9mm-length-440mm
402.340 -Diameter,10mm-length-340mm
402.360 -Diameter,10mm-length-360mm
402.380 -Diameter, 10mm-length-380mm
402.400 -Diameter, 10mm-length-400mm
402.420 -Diameter, 10mm-length-420mm
402.440 -Diameter, 10mm-length-440mm
402.460 -Diameter, 10mm-length-460mm
403.340 -Diameter, 11mm-length-340mm
403.360 -Diameter, 11mm-length-360mm
403.380 -Diameter, 11mm-length-380mm
403.400 -Diameter, 11mm-length-400mm
403.420 -Diameter, 11mm-length-420mm
403.440 -Diameter, 11mm-length-440mm
403.460 -Diameter, 11mm-length-460mm
404.340 -Diameter, 12mm-length-340mm
404.360 -Diameter, 12mm-length-360mm
404.380 -Diameter, 12mm-length-380mm
404.400 -Diameter, 12mm-length-400mm
404.420 -Diameter, 12mm-length-420mm
404.440 -Diameter, 12mm-length-440mm
404.460 -Diameter, 12mm-length-460mm
405.340 -Diameter, 13mm-length-340mm
405.360 -Diameter, 13mm-length-360mm
405.380 -Diameter, 13mm-length-380mm
405.400 -Diameter, 13mm-length-400mm
405.420 -Diameter, 13mm-length-420mm
405.440 -Diameter, 13mm-length-440mm
405.460 -Diameter, 13mm-length-460mm
SCREWS: 4.9mm Locking Bolt lengths are 22mm, 24mm, 26mm, 28mm, 30mm, 32mm, 34mm, 36mm, 38mm, 40mm, 42mm, 44mm, 46mm, 48mm, 50mm, 52mm, 54mm, 56mm, 58mm, 60mm, 65mm, 70mm, 75mm, 80mm, 85mm, 90mm, 95mm and 100mm.
Femur (Femoral) Nail is indicated for use in a variety of femoral fractures such as:
- Comminuted fractures
- Segmental fractures
- Fractures with bone loss
- Proximal and distal fractures
- Nonunions
- Subtrochanteric fractures
- Intertrochanteric fractures
Cannulated Femoral Nail (C.F.N) Contraindications: The physician’s education, training and professional judgement must be relied upon to choose the most appropriate device and treatment. Conditions presenting an increased risk of failure include:
- Any active or suspected latent infection or marked local inflammation in or about the affected area.
- Compromised vascularity that would inhibit adequate blood supply to the fracture or the operative site.
- Bone stock compromised by disease, infection or prior implantation that can not provide adequate support and/or fixation of the devices.
- Material sensitivity, documented or suspected.
- Obesity. An overweight or obese patient can produce loads on the implant that can lead to failure of the fixation of the device or to
failure of the device itself. - Patients having inadequate tissue coverage over the operative site.
- Implant utilization that would interfere with anatomical structures or physiological performance.
- Any mental or neuromuscular disorder which would create an unacceptable risk of fixation failure or complications in postoperative care.
- Other medical or surgical conditions which would preclude the potential benefit of surgery.
Manufactured from High Quality Medical Grade Stainless Steel German and Titanium. 100% Brand New & High Quality. 100% Customer Satisfaction Guaranteed. Ultrasonic Cleaned-QC Passed. Condition: Brand New (Perfection and Excellent Quality). Manufacturer by MÜNCHEN STEEL®